The MCD Elektronik test system for CO₂ measuring cells enables high-precision tests under realistic pressure conditions.
The test system for CO₂ measuring cells was developed for high-precision validation of measuring cells used in industrial plants to determine CO₂ concentration in gaseous media. Testing under defined pressure conditions must be precise, reproducible and designed for high volumes.

Blinker, Kamera, Heizung und Assistenzsysteme.
Special Systems
Außenspiegel
Precise pressure tests
For this purpose, MCD Elektronik implemented a pressure-tight test chamber made of solid stainless steel, which is flooded with CO₂ and pressurized to up to 2.5 bar. This allows real operating conditions to be reproduced and the measuring cells to be validated under reproducible conditions.
Up to 20 units can be tested in parallel in one test run. Pressure-resistant encapsulated measurement lines prevent leaks and distorted measurements, while the robust design supports reliable continuous industrial operation.
Ein flexibler End-of-Line-Prüfstand
MCD entwickelte hierfür einen flexiblen End-of-Line-Prüfstand, der sämtliche Varianten innerhalb von weniger als 30 Sekunden prüft. Das System kombiniert optische, mechanische und elektrische Prüfverfahren zu einem durchgängigen Prüfkonzept.
Produktvarianten
Produktvarianten
Über 30
- Taktzeit pro Bauteil
- Taktzeit pro Bauteil
Unter 30 s
Qualitätskontrolle vor Auslieferung
Qualitätskontrolle vor Auslieferung
100 %
Produktvarianten
Produktvarianten
Über 30
- Taktzeit pro Bauteil
- Taktzeit pro Bauteil
Qualitätskontrolle vor Auslieferung
Qualitätskontrolle vor Auslieferung
100 %
The test system reproduces real pressure conditions for CO₂ measuring cells and combines a pressure-tight test chamber with parallel multiple testing and robust system integration:



The CO₂ measuring cells are tested in a pressure-tight stainless steel chamber under defined and reproducible pressure conditions.
- Pressure-tight CO₂ test chamber made of solid stainless steel
- Operating pressure up to 2.5 bar
- Flooding the test chamber with CO₂
- Realistic and reproducible test conditions
The test platform is designed for high throughput and enables several measuring cells to be tested simultaneously.
- Parallel testing of up to 20 units per test run
- Efficient processing of high volumes
- Reproducible test conditions for all units
- Designed for industrial series production
The entire measurement system is designed for reliable pressure tightness and to prevent distorted measurements.
- Pressure-resistant encapsulated measurement lines
- Prevention of leaks
- Prevention of distorted measurements
- Robust test platform for high-precision measuring cells
The test setup is mounted on a standard ULC rack and can be integrated into existing production environments.
- Mounted on a stable standard ULC rack
- Integration into existing production environments
- Designed for demanding industrial applications
- Robust construction for continuous operation


Einblick in die MCD Prüflösung
Variantenspezifische Prüflogik
Der Prüfstand überprüft sämtliche vorhandenen Funktionen des Außenspiegels:
Spiegeleinstellungen
Kamerasysteme kontrollieren Lichtfunktionen und Spiegelstellungen, während Antriebe, Klappmechanismen und elektrische Funktionen automatisiert getestet werden.
Verstell- und Klappfunktion
Spiegelheizung
EC-Abblendglas
Lichtfunktionen
Blinker
Spurwechselassistent
Umfeldbeleuchtung
Kamerafunktion
Unterschiedliche Ausstattungsmerkmale werden automatisch erkannt und gezielt geprüft.
Kamerafunktion
Länderspezifische Varianten
Auch das Nichtvorhandene zählt.
Die Negativprüfung stellt sicher, dass sich nicht verbaute Ausstattungsmerkmale nicht aktivieren lassen. Geprüft wird auch, was fehlen muss.
Parallel testing of up to 20 CO₂ measuring cells combines high throughput with reproducible test conditions and precise validation under pressure.
The test system combines a pressure-tight test chamber with central test software, precise control, unambiguous unit identification and MES connectivity. This ensures that test sequences are controlled, monitored and documented transparently.
Prüfung komplexer Ausstattungsvarianten
Sichere Erkennung von Fehlerbildern
Reproduzierbare Ergebnisse
Optische Prüfungen
Kamerabasierte Erkennung von Lichtfunktionen
Analyse von Spiegelstellungen
Kontrolle des Spiegelglases
Mechanische und elektrische Prüfungen
Bewegungsprüfung der Antriebe
Winkelmessung der Klappfunktion
Stromaufnahme der Motoren
Prüfung komplexer Ausstattungsvarianten
Sichere Erkennung von Fehlerbildern
Reproduzierbare Ergebnisse
FREQUENTLY ASKED QUESTIONS
FAQS
KEY FACTS
Key facts at a glance
Measuring cell testing: testing of CO₂ measuring cells under realistic conditions.
Traceability: barcode-based identification and pass/fail assignment.